JEL Clarifier Dynamics

JEL Clarifier Dynamics

Layered secondary clarifier model run over a flow time series: sludge blanket, RAS and MLSS through the day. Everything runs in your browser.

Average clarifier

Worst lane

Plant solids

    Time series

    Click or drag on the chart to move the playhead. The cross-section and state point below follow it.

    —
    Average clarifier Worst lane Forward flow RAS flow MLSS, clarifier feed MLSS, pass 1 Blanket alarm level Feed level

    Clarifier cross-section

    Layer concentrations at the playhead. Left half average, right half worst lane.

    Where the solids areMLSS mg/LSolids t

    State point at the playhead

    Same construction as JEL State Point, using the flows and MLSS at this instant. Axes stay fixed for the whole run.

    Gravity flux Overflow line Underflow, average Underflow, worst lane Critical underflow line Hollow ring: modelled RAS concentration

    At the playhead

    QuantityAverageWorst lane

    Whole run

    ResultAverageWorst lane

    How it works

    Clarifier: layered flux model

    Each clarifier is a column of equal horizontal layers (Takács et al., 1991). Feed enters the layer at the feed level. Water moves up from there at Q/A and down at QRAS/A, carrying solids with it. Between layers, solids settle at the Vesilind gravity flux G = X·V₀·e−KX, limited to the smaller of the two layers' fluxes so a thick layer cannot settle into a thicker one. Above the feed, that limit only applies once the lower layer passes 3 g/L, so dilute solids in the clarification zone settle freely.

    dXⱼ/dt = [ bulk flux in − bulk flux out + settling flux in − settling flux out ] / Δz

    This is what lets a blanket form, hold solids, and rise or fall as loading changes, which the static state point cannot do.

    Aeration: where the solids come from

    In step feed, all the RAS enters the start of pass 1 and the forward flow is split between the passes. Each pass is a chain of equal mixed cells, and each cell balances the solids flowing in and out:

    Vcell·dXi/dt = (QRAS + Fi−1·Q)·Xi−1 − (QRAS + Fi·Q)·Xi

    Fi is the fraction of forward flow that has joined by cell i, and the first cell takes RAS at XRAS. At steady state a pass runs at Xfeed·(QRAS + Q)/(QRAS + F·Q), so with an even 4-pass split and RAS at half the forward flow, pass 1 holds twice the clarifier feed MLSS. The plant therefore stores more solids than a fully mixed tank at the same clarifier feed MLSS, mostly up front. When forward flow rises, the front passes are diluted and their solids are pushed toward the clarifiers over a few hours, rather than all at once. Fully mixed mode treats the aeration as one tank, as in v1.0.

    Total solids in aeration plus clarifiers is conserved, apart from the small amount lost in the effluent. When a storm pushes the clarifiers into thickening failure, solids move into the blanket, MLSS falls, the applied flux eases and the system can rebalance. Held mode switches this off and keeps MLSS fixed, which gives a worst case. From data mode uses a measured MLSS column.

    Examples

    All three are synthetic, at 15-minute steps, scaled to the example average flow. Dry weather follows a typical diurnal profile. Wet weather is a dry day followed by a storm from hour 30 that adds 110% of the average flow over a 3-hour rise and 6-hour hold, then recedes. Constant flow holds the average for 48 hours: after the warm-up the clarifier should sit at the same steady state JEL State Point gives for the same inputs, which is a useful check.

    Worst lane

    The worst lane is one clarifier fed at the worst-lane factor times the plant MLSS, with the same flows per clarifier. It is one clarifier among many, so the solids it stores do not change plant MLSS. The factor is a fixed ratio, so this does not model the lane runaway where a lane's own RAS raises its feed concentration further.

    Reading the results

    • Blanket height is read the way a sludge judge reads it: scanning down from the surface to the first layer at or above the blanket interface value, interpolated between layer centres.
    • Sludge above the feed settles to the concentration where its settling velocity matches the upflow, X = ln(V₀/q)/K. At storm overflow rates this is roughly 3–4.5 g/L, so it is set by the overflow rate rather than by thickening. Keep the interface value below it (the default is 3,000 mg/L), or a rising blanket above the feed will be missed.
    • Layer count matters. Coarse layers smear the blanket upward. On the wet-weather example the peak average blanket is about 1.1 m with 10 layers, 0.6 m with 40 and 0.5 m with 80, so 40 is the default. Takács used 10; use 10 only to compare with other models built that way.
    • Effluent SS is sludge carried over from the top layer. The settling model has no non-settleable fraction, so it reads near zero until the blanket reaches the surface. Treat it as a carry-over indicator, not a predicted effluent quality.
    • Thickening failure hours count the time the instantaneous state point is above the limiting flux. The blanket can stay low through a short failure because it takes time to fill.

    Assumptions

    • Flow splits evenly across the clarifiers in service. Influent solids, sludge growth and WAS are ignored over the run, which suits runs of a few days.
    • No compression model: below the blanket the settling rule is the same Vesilind flux, so RAS concentrations in heavy blankets may read high.
    • Each run starts with a warm-up at the first data row's flows and the starting MLSS, so the clarifier begins near steady state. If the first row is already overloaded, the blanket grows during the warm-up and the tool warns you.
    • Data between time points is linearly interpolated. The model steps at a few minutes or less, set by the layer thickness and settling velocity.